Abstract
Surface transfer impedance measurements of overlapping cable braids on a large cable showed that the transfer impedance of this joining technique was not a sensitive function of the amount of overlap or the technique for applying pressure to the braids. Measurements of the transfer impedance of a hose clamp braid termination that increased the braid diameter by a almost a factor of three showed that the low frequency transfer impedance of the braid termination was about 1/6 of the low frequency transfer impedance of a meter of cable. The high frequency transfer impedance of the hose clamp braid termination was about 1/12 that of a meter of cable
Keywords
cable jointing; cable sheathing; electric impedance measurement; 1 m; braid diameter; high frequency transfer impedance; hose clamp braid termination; hose clamp shield terminations; joining technique; low frequency transfer impedance; overlapping braided cable shields; pressure; surface transfer impedance measurements; Cable shielding; Clamps; Connectors; Fixtures; Frequency; Hoses; Impedance measurement; Power cables; Surface impedance; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1995. Symposium Record., 1995 IEEE International Symposium on
Conference_Location
Atlanta, GA
Print_ISBN
0-7803-3608-9
Type
conf
DOI
10.1109/ISEMC.1995.523605
Filename
523605
Link To Document