DocumentCode :
3332547
Title :
Transfer impedance of overlapping braided cable shields and hose clamp shield terminations
Author :
Hoeft, Lothar O. ; Hofstra, Joseph S.
Author_Institution :
BDM Federal Inc., Albuquerque, NM, USA
fYear :
195
fDate :
14-18 Aug 195
Firstpage :
480
Lastpage :
482
Abstract :
Surface transfer impedance measurements of overlapping cable braids on a large cable showed that the transfer impedance of this joining technique was not a sensitive function of the amount of overlap or the technique for applying pressure to the braids. Measurements of the transfer impedance of a hose clamp braid termination that increased the braid diameter by a almost a factor of three showed that the low frequency transfer impedance of the braid termination was about 1/6 of the low frequency transfer impedance of a meter of cable. The high frequency transfer impedance of the hose clamp braid termination was about 1/12 that of a meter of cable
Keywords :
cable jointing; cable sheathing; electric impedance measurement; 1 m; braid diameter; high frequency transfer impedance; hose clamp braid termination; hose clamp shield terminations; joining technique; low frequency transfer impedance; overlapping braided cable shields; pressure; surface transfer impedance measurements; Cable shielding; Clamps; Connectors; Fixtures; Frequency; Hoses; Impedance measurement; Power cables; Surface impedance; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1995. Symposium Record., 1995 IEEE International Symposium on
Conference_Location :
Atlanta, GA
Print_ISBN :
0-7803-3608-9
Type :
conf
DOI :
10.1109/ISEMC.1995.523605
Filename :
523605
Link To Document :
بازگشت