DocumentCode :
3332888
Title :
Investigation of the performance of an electrothermal plasma source with extended pulse length
Author :
Winfrey, L. ; Gilligan, J. ; Bourham, M. ; Al-Halim, M.A.
Author_Institution :
North Carolina State Univ., Raleigh, NC, USA
fYear :
2010
fDate :
20-24 June 2010
Firstpage :
1
Lastpage :
1
Abstract :
Summary form only given. Electrothermal (ET) plasma sources operating in the ablation-controlled arc regime uses discharge currents with pulse lengths between 100 μs to 1 ms. Faster or longer or extended flat-top pulses can also be generated to satisfy various applications of ET sources. It was reported that shorter pulse length of about 300 ms is more powerful but provided shorter time duration for the interaction of the plasma flow with a solid target, and that the pulse is a key parameter for effective ignition of plasma propellant interactions.In this study, a circuit equation is incorporated in the electrothermal plasma code ETFLOW to generate desired pulse forms of the discharge current through varying the pulse power lumped circuit parameters, while the pulse amplitude is controlled via the input charging voltage. Pulse length for fast rise short pulses between 5 to lOOμs were generated and used in the code to calculate plasma exit parameters. Current pulses with extended flat-top were also used to predict the performance for flat-top pulses up to 1000μs. Code calculations for Lexan polycarbonate, using both ideal and nonideal plasma models, have shown that the source exit parameters, with extended flat-top pulses at fixed amplitude, produce more ablated mass which scales linearly with increased flat-top pulse length up to 1000μs. However, other plasma parameters remain almost constant. This result suggests that quasi-steady state operation of ET source may provide constant exit pressure and plasma bulk velocity useful for thrusters applications. For short pulses 5-100μs with constant amplitude, the plasma exit pressure varied between 60 to 410 MPa and the plasma velocity increased from -1.2 to 8.2 km/s. The total ablated mass for 5-100μs short pulse lengths increases with increased pulse length but with lower rate, which is consistent with published results, obtained using polyethylene capillary discharge.
Keywords :
arcs (electric); plasma applications; plasma flow; plasma pressure; plasma simulation; plasma sources; plasma transport processes; polymers; ETFLOW; Lexan polycarbonate; ablation-controlled arc regime; discharge current; electrothermal plasma code; electrothermal plasma source; extended pulse length; flat-top pulse length; nonideal plasma model; plasma bulk velocity; plasma exit pressure; plasma flow interaction; plasma propellant interaction; polyethylene capillary discharge; pulse amplitude; pulse power lumped circuit parameter; quasisteady state operation; short pulse length; total ablated mass; Electrothermal effects; Equations; Fault location; Ignition; Plasma applications; Plasma sources; Propulsion; Pulse circuits; Pulse generation; Solids;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science, 2010 Abstracts IEEE International Conference on
Conference_Location :
Norfolk, VA
ISSN :
0730-9244
Print_ISBN :
978-1-4244-5474-7
Electronic_ISBN :
0730-9244
Type :
conf
DOI :
10.1109/PLASMA.2010.5534206
Filename :
5534206
Link To Document :
بازگشت