    The study of saturation effect of GEM detector for X-ray imaging

  • Author

    Tian, Yang ; Li, Yulan ; Li, Yuanjing ; Yang, Yigang ; Qi, Huirong ; Li, Ting

  • Author_Institution
    Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    687
  • Lastpage
    689
  • Abstract
    In our lab, an imaging detector prototype based on gas electron multiplier (GEM) was successfully designed and constructed. During the systematic response measurement of this device, an unexpected saturation phenomenon was highlighted. When the effective gas gain is increased, apparent saturation effect is observed. At high pressure, such as 2 atm or 3 atm, there is a similar phenomenon. Taking into account drift voltage, effective gas gain, area effect and resistive network, we now significantly diminish the saturation of the detector´s response and get some useful results.
  • Keywords
    X-ray imaging; electron multiplier detectors; ionisation chambers; X-ray imaging; detector response; drift voltage; effective gas gain; gas electron multiplier detector; imaging detector prototype; resistive network; saturation effect; systematic response measurement; Electron multipliers; Optical imaging; Prototypes; Space charge; Steel; System testing; Voltage; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5402038
  • Filename
    5402038