DocumentCode
3334662
Title
Notice of Retraction
Rapid Determination of Volatile Chlorinated Hydrocarbons Using PID Combined with RAE-SEP Tube
Author
Lingrong Tang ; Mei Wan ; Rui Liu ; Xiaogang Wen ; Qiang Cai ; Lvjun Chen
Author_Institution
Coll. of Life & Environ. Sci., Shanghai Normal Univ., Shanghai, China
fYear
2011
fDate
10-12 May 2011
Firstpage
1
Lastpage
3
Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
Volatile chlorinated hydrocarbons were detected by photo ionization detector. The halogenated hydrocarbon RAE-SEP tubes were used to remove the interference of Benzene Toluene Ethylbenzene & Xylene (BTEX). The results show that tetrachloroethene, trichloroethene, cis-1, 2-dichloroethene, benzene, toluene and ethyl benzene have good linear response on PID. The halogenated hydrocarbon RAE-SEP tubes exhibit good separation of BTEX from volatile chlorinated hydrocarbons confirmed by GC analysis. So PID combined with halogenated hydrocarbon RAE-SEP tubes could be used for the on-situ monitoring of volatile chlorinated hydrocarbons in soil and groundwater.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
Volatile chlorinated hydrocarbons were detected by photo ionization detector. The halogenated hydrocarbon RAE-SEP tubes were used to remove the interference of Benzene Toluene Ethylbenzene & Xylene (BTEX). The results show that tetrachloroethene, trichloroethene, cis-1, 2-dichloroethene, benzene, toluene and ethyl benzene have good linear response on PID. The halogenated hydrocarbon RAE-SEP tubes exhibit good separation of BTEX from volatile chlorinated hydrocarbons confirmed by GC analysis. So PID combined with halogenated hydrocarbon RAE-SEP tubes could be used for the on-situ monitoring of volatile chlorinated hydrocarbons in soil and groundwater.
Keywords
chromatography; groundwater; organic compounds; photoionisation; soil pollution; water pollution measurement; BTEX separation; GC analysis; benzene toluene ethylbenzene; cis-1, 2-dichloroethene; ethyl benzene; groundwater; halogenated hydrocarbon RAE-SEP tubes; on-situ monitoring; photoionization detector; soil; tetrachloroethene; trichloroethene; vacuum ultraviolet lamp; volatile chlorinated hydrocarbon of; volatile chlorinated hydrocarbons; xylene; Detectors; Electron tubes; Gases; Hydrocarbons; Ionization; Soil; Volatile organic compounds;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering, (iCBBE) 2011 5th International Conference on
Conference_Location
Wuhan
ISSN
2151-7614
Print_ISBN
978-1-4244-5088-6
Type
conf
DOI
10.1109/icbbe.2011.5780918
Filename
5780918
Link To Document