DocumentCode
3335014
Title
Simulation of pseudo-clinical conditions and image quality evaluation of PET scanner based on pixelated CdTe detector
Author
Mikhaylova, Ekaterina ; Cañadas, Mario ; De Lorenzo, Gianluca ; Chmeissani, Mokhtar ; Arce, Pedro ; Ariño, Gerard ; Cabruja, Enric ; Calderón, Yonatan ; Kolstein, Machiel ; Macias-Montero, Jose Gabriel ; Martinez, Ricardo ; Ozsahin, Ilker ; Puigdengoles,
Author_Institution
Inst. de Fis. d´´Altes Energies (IFAE), Univ. Autonoma de Barcelona (UAB), Bellaterra, Spain
fYear
2011
fDate
23-29 Oct. 2011
Firstpage
2716
Lastpage
2722
Abstract
A novel conceptual design of PET scanner, known as a Voxel Imaging PET (VIP) [1], based on pixelated solid state detector, has been proposed to overcome the intrinsic limitations of state-of-art PET devices based on scintillating crystals. For this study, the VIP scanner has been simulated in different pseudo-clinical conditions in order to assess its image quality performance. The evaluation of the PET image quality follows the NEMA prescriptions. Results are also presented for both analytic and iterative image reconstruction methods. The preliminary results from simulations show that the image reconstruction performance of the VIP scanner under realistic clinical conditions provides good images with low dose. The VIP scanner is able to detect down to 1 mm in diameter hot regions in small phantoms without background activity and down to 5 mm in diameter hot spheres in big phantoms in the presence of background activity. Moreover, good quality and high contrast images can be obtained with a considerably lower number of coincidences with respect to the usual crystal PETs.
Keywords
II-VI semiconductors; cadmium compounds; image reconstruction; image scanners; iterative methods; medical image processing; phantoms; positron emission tomography; solid scintillation detectors; CdTe; NEMA prescription; PET image quality; PET scanner; VIP scanner; high contrast image; image quality evaluation; iterative image reconstruction method; phantoms; pixelated detector; pixelated solid state detector; pseudoclinical condition; scintillating crystals; voxel imaging PET; Biomedical imaging; Image quality; Image reconstruction; Ions; Materials; Pediatrics;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location
Valencia
ISSN
1082-3654
Print_ISBN
978-1-4673-0118-3
Type
conf
DOI
10.1109/NSSMIC.2011.6152955
Filename
6152955
Link To Document