DocumentCode
3337909
Title
Notice of Retraction
Study of Propylene Oxide Wastewater Treatment with Scrap Iron-H2O2
Author
Lan Shanhong ; Wu Xiuwen
Author_Institution
Coll. of Chem. & Environ. Eng., Dongguan Univ. of Technol., Dongguan, China
fYear
2011
fDate
10-12 May 2011
Firstpage
1
Lastpage
3
Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
In this paper, a new technology with lower cost but more effective that treating propylene oxide wastewater with scrap iron-H2O2 was studied. The effects of the pH of initial reaction, the concentration of scrap iron and H2O2 and the reaction time on the treatment of propane wastewater were also studied. The results showed that CODCr removal rate could achieve 70% on the reaction conditions which the pH of early reaction was 2, the iron powder capacity 12 g · L-1, the concentration of H2O2 3.2 mL · L-1, and the reaction time 40 min. It indicated that the cost was 3.5 Yuan to treat one ton Propylene oxide wastewater by economic analysis.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
In this paper, a new technology with lower cost but more effective that treating propylene oxide wastewater with scrap iron-H2O2 was studied. The effects of the pH of initial reaction, the concentration of scrap iron and H2O2 and the reaction time on the treatment of propane wastewater were also studied. The results showed that CODCr removal rate could achieve 70% on the reaction conditions which the pH of early reaction was 2, the iron powder capacity 12 g · L-1, the concentration of H2O2 3.2 mL · L-1, and the reaction time 40 min. It indicated that the cost was 3.5 Yuan to treat one ton Propylene oxide wastewater by economic analysis.
Keywords
iron; pH; scrap metal; wastewater treatment; COD removal rate; economic analysis; iron powder capacity; pH; propane wastewater treatment; propylene oxide wastewater treatment; scrap iron concentration; Companies; Economics; Iron; Oxidation; Powders; Wastewater; Wastewater treatment;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering, (iCBBE) 2011 5th International Conference on
Conference_Location
Wuhan
ISSN
2151-7614
Print_ISBN
978-1-4244-5088-6
Type
conf
DOI
10.1109/icbbe.2011.5781110
Filename
5781110
Link To Document