Feasibility study and first results of a real time imaging dosimeter for external beam radiation therapy
Author
Price, S.G. ; Silvius, A.A. ; Izaguirre, E.W.
Author_Institution
Sch. of Med., Washington Univ. in St. Louis, St. Louis, MO, USA
fYear
2011
fDate
23-29 Oct. 2011
Firstpage
2822
Lastpage
2826
Abstract
The purpose of this study was to determine the feasibility of building an in vivo dosimeter prototype to perform real time dosimetry to detect treatment errors in intensity modulated radiation therapy (IMRT). The dosimeter will enhance patient safety through real time verification of treatment dose when real time beam measurements are compared against treatment plan pre-computed doses. The high speed dosimeter is based on scintillating fiber arrays embedded in a water equivalent plastic support. The fibers are aligned to match each multileaf collimator (MLC) leaf pair and placed in the accessory tray of the LINAC. Each fiber is coupled to a pair of silicon photomultiplier and high speed front end amplifiers to read the scintillator output. The dosimeter response was tested with a broad selection of clinical beam energies, dose rates, and MLC positions and the scintillating fiber sensor output correlated linearly with these parameters. The front end electronics have a response time of 0.2 μsec, thus every beam radiation pulse can be recorded to verify the beam fluence with high precision. The plastic support and fibers provide a beam attenuation of 2.65%, minimal enough to utilize this technology as an in vivo transmission detector at the head of the LINAC. The linear response of output versus MLC beamlet opening provides a measurement of each leaf position with a precision of 1.5 mm. The designed real time imaging dosimeter will use five of these scintillating fiber arrays to reconstruct delivered beam fluences in vivo and compare them in real time against the treatment plan. Should an error occur, the software will notify the therapist or halt the treatment. The reported work shows a proof and initial results of the feasibility of constructing a scintillating fiber array for in vivo real time dosimetry to enhance patient safety and treatment verification accuracy in external beam radiotherapy.
Keywords
collimators; dosimetry; patient treatment; photodetectors; photomultipliers; radiation therapy; scintillation; silicon; LINAC; Si; amplifiers; beam attenuation; clinical beam energies; external beam radiation therapy; intensity modulated radiation therapy; multileaf collimator leaf pair; patient safety; patient treatment verification accuracy; real time imaging dosimeter; scintillating fiber arrays; scintillating fiber sensor; silicon photomultiplier; time 0.2 mus; transmission detector; water equivalent plastic support; Biomedical imaging; Image resolution; In vivo; Medical treatment; Optical fiber testing; Silicon; Solids;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location
Valencia
ISSN
1082-3654
Print_ISBN
978-1-4673-0118-3
Type
conf
DOI
10.1109/NSSMIC.2011.6153646
Filename
6153646
Link To Document