Title :
Compressed sensing for the multiplexing of PET detectors
Author :
Olcott, Peter D. ; Chinn, Garry ; Levin, Craig S.
Abstract :
Compressed sensing can be used to multiplex a large number of individual readout sensors to significantly reduce the number of readout channels in a large area PET block detector. The compressed sensing framework can be used to treat PET data acquisition as a sparse readout problem and achieve sub-Nyquist rate sampling, where the Nyquist rate is determined by the pixel pitch of the individual SiPM sensors. The sensing matrix is fabricated by using discrete elements or wires that uniquely connect pixels to readout channels. By analyzing the recorded magnitude on several ADC channels, the original pixel values can be recovered even though they have been scrambled through a sensing matrix. In a PET block detector design comprising 128 SiPM pixels arranged in a 16 × 8 array, compressed sensing can provide higher multiplexing ratios (128:16) than Anger logic (128:32) or Cross-strip readout (128:24) schemes while resolving multiple simultaneous hits. Unlike Anger and cross-strip multiplexing, compressed sensing can recover the positions and magnitudes of simultaneous, multiple pixel hits. Decoding multiple pixel hits can be used to improve the positioning of events in light-sharing designs, inter-crystal scatter events, or events that pile up in the detector. A Monte-carlo simulation of a compressed sensing multiplexed circuit design for a 16 × 8 array of SiPM pixels was done. Noise sources from the SiPM pixel (dark counts) and from the readout channel (thermal noise) were included in the simulation. Also, two different crystal designs were simulated, a 1×1 coupled design with 128 scintillation crystals, and a 3:2 light-sharing design with 196 crystals. With an input SNR of 37dB (experimentally measured from a single SiPM pixel), all crystals were clearly decoded by the compressed sensing multiplexing with a decoded SNR of the sum signal a 30.6 ± 0.1 dB SNR for the one-to-one coupling, and 26.1 ± 0.1 dB three-to-two coupling. For a- 10% energy resolution, and SNR of greater than 20 dB is needed to accurately recover the energy.
Keywords :
Monte Carlo methods; biomedical equipment; compressed sensing; medical signal detection; multiplexing; photodetectors; positron emission tomography; readout electronics; solid scintillation detectors; ADC channels; Anger logic comparison; Monte Carlo simulation; PET data acquisition; PET detector multiplexing; SiPM pixel noise sources; SiPM sensor pixel pitch; compressed sensing multiplexed circuit design; cross strip readout comparison; dark counts; event positioning; intercrystal scatter events; large area PET block detector; light sharing design; multiplexing ratio; readout channel noise sources; readout channels; readout sensors; scintillation crystals; sensing matrix; sparse readout problem; subNyquist rate sampling; thermal noise; Indexes; Marine vehicles; Positron emission tomography; Signal to noise ratio;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
Print_ISBN :
978-1-4673-0118-3
DOI :
10.1109/NSSMIC.2011.6153661