DocumentCode :
3341545
Title :
3D structural analysis of ground-wall insulation of AC rotating machines using X-ray tomography
Author :
Contin, Alfredo ; Schena, G. ; Dreossi, Diego
Author_Institution :
DIA, Univ. of Trieste, Trieste, Italy
fYear :
2013
fDate :
June 30 2013-July 4 2013
Firstpage :
279
Lastpage :
282
Abstract :
The X-ray computed tomography has been applied here to inspect the internal features of two types of ground-wall insulation systems of ac rotating machines. Samples extracted from complete coils were scanned and their internal structure was analyzed by means of virtual slicing and 3D rendering procedures. Specialized software tools have been used to discover the morphological features of both the distributed voids and the high-density anomalies. It is was found that the resin penetration as well as the density and the geometries of the distributed microvoids depend from the tape characteristics.
Keywords :
AC machines; X-ray microscopy; computerised tomography; electric machine analysis computing; machine insulation; rendering (computer graphics); 3D rendering procedures; 3D structural analysis; AC rotating machines; X-ray computed tomography; distributed microvoids; distributed voids; ground-wall insulation; ground-wall insulation systems; internal structure analysis; resin penetration; software tools; tape characteristics; virtual slicing; Coils; Digital images; Image segmentation; Insulation; Resins; Solids; Three-dimensional displays; ground-wall insulation; rotating machines; x-ray tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Solid Dielectrics (ICSD), 2013 IEEE International Conference on
Conference_Location :
Bologna
ISSN :
2159-1687
Print_ISBN :
978-1-4799-0807-3
Type :
conf
DOI :
10.1109/ICSD.2013.6619750
Filename :
6619750
Link To Document :
بازگشت