DocumentCode :
3341655
Title :
Direct 3D PET image reconstruction into MR image space
Author :
Gravel, Paul ; Verhaeghe, Jeroen ; Reader, Andrew J.
Author_Institution :
McConnell Brain Imaging Center, McGill Univ., Montreal, QC, Canada
fYear :
2011
fDate :
23-29 Oct. 2011
Firstpage :
3955
Lastpage :
3962
Abstract :
A method which includes both the motion correction and image registration transformation parameters from PET image space to MR image space within the system matrix of the MLEM algorithm is presented. This approach can be of particular significance in the fields of neuroscience and psychiatry, whereby PET is used to investigate differences in activation patterns between groups of participants (such as healthy controls and patients). This requires all images to be registered in a common spatial atlas. Currently, image registration is performed post-reconstruction. This introduces interpolation effects in the final image and causes image resolution degradation. Furthermore, motion correction introduces a further level of interpolation and possible resolution degradation. To include the transformation parameters (both for motion correction and registration) within the iterative PET reconstruction framework (through iterative use of actual software packages routinely applied after reconstruction) should reduce these interpolation effects and thus improve image resolution. Furthermore, it opens the possibility of direct reconstruction of the PET data into standardized stereotaxic atlases, e.g. ICBM152. To validate the proposed method, this work investigates registration, using 2D and 3D simulations based on the HRRT scanner geometry, between different image spaces using rigid body transformation parameters calculated using the mutual information similarity criterion. The quality of reconstruction was assessed using bias-variance and mean absolute error analyses to quantify differences with current post-reconstruction registration methods. We demonstrate a reduction in bias and in mean absolute error in reconstructed mean ROI activity when using the proposed method.
Keywords :
image reconstruction; image registration; image resolution; medical image processing; neurophysiology; positron emission tomography; HRRT scanner geometry; ICBM152; MLEM algorithm; MR image space; activation pattern; direct 3D PET image reconstruction; image registration; image resolution degradation; interpolation effect; motion correction; neuroscience; psychiatry; transformation parameters; Image reconstruction; Phantoms; Spatial resolution; Three dimensional displays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
ISSN :
1082-3654
Print_ISBN :
978-1-4673-0118-3
Type :
conf
DOI :
10.1109/NSSMIC.2011.6153752
Filename :
6153752
Link To Document :
بازگشت