    Combined effects of pulse pile-up and energy response in energy-resolved, photon-counting computed tomography

  • Author

    Roessl, Ewald ; Daerr, Heiner ; Engel, Klaus Jürgen ; Thran, Axel ; Schirra, Carsten ; Proksa, Roland

  • Author_Institution
    Philips Res. Labs. - Hamburg, Hamburg, Germany
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    2309
  • Lastpage
    2313
  • Abstract
    The very high x-ray flux rates employed in today´s human computed tomography (CT) scanners in order to keep scanning times at a conveniently low level constitute the most challenging obstacle to the advent of clinical, photon-counting (spectral) CT. Even with most sophisticated, application-specific, energy-discriminating, photon-counting readout electronics, designed for room-temperature semi-conductor sensors like CdTe or CZT, the effects of spectral degradation due to pulse pile-up, i.e., count rate losses and gains will have to be taken into account in a clinical setting. The energy registered in a first-order pile-up event (superposition of two pulses) depends strongly on the energies of the two primaries involved, the difference in their arrival times and the spectral detector response behavior. We present an analytic model for the number of expected counts in binned photon-counting detectors, which is based on work by Wielopolski and Gardner and takes into account the combined effects of a spectral detector response function and 1st order pulse pile-up. The analytic model is validated by means of Monte-Carlo simulations and is applied to a simulation of a clinical spectral CT scenario in the context of K-edge imaging of a high-atomic number element as a contrast material. The artifacts in the reconstructed single-bin images and their manifestation in material-decomposed images are discussed and interpreted in terms of gains and losses of counts due to pile-up. Finally, we discuss the shortcomings of the model like the limitation to 1st order pile-up and the inherent restriction of the Wielopolski-Gardner model to peak pile-up.
  • Keywords
    computerised tomography; photon counting; semiconductor counters; K-edge imaging; Monte-Carlo simulations; Wielopolski-Gardner model; X-ray flux rates; clinical spectral CT scenario; energy response; high-atomic number element; human computed tomography scanners; photon-counting computed tomography; photon-counting detectors; photon-counting readout electronics; pulse pile-up; reconstructed single-bin images; room-temperature semiconductor sensors; scanning times; Detectors; Photonics; Shape; computed tomography; energy-sensitive; photon-counting detectors; pulse pile-up;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6153869
  • Filename
    6153869