DocumentCode
334521
Title
Prediction of anechoic chamber radiated emissions measurements through use of empirically-derived transfer functions and laboratory common-mode current measurements
Author
Smith, William T. ; Frazier, R. Keith
Author_Institution
Dept. of Electr. Eng., Kentucky Univ., Lexington, KY, USA
Volume
1
fYear
1998
fDate
24-28 Aug 1998
Firstpage
387
Abstract
In this study common-mode current measurements made in a laboratory (without an anechoic chamber) were correlated with radiated emissions measurements (made in an anechoic chamber) over a broad frequency range. The goal was to evaluate the use of current measurements as an alternative to avoid repeated testing of an electronic device in an anechoic chamber while improvements are made to the device during the design phase. Empirical transfer functions based on current and field measurements made in an anechoic chamber are used with laboratory (nonanechoic chamber) measured common-mode current data for prediction of radiated emissions. Comparisons are made between the fields data measured in an anechoic chamber and the predicted fields data based on the laboratory common-mode current measurements
Keywords
anechoic chambers (electromagnetic); electric current measurement; electromagnetic interference; transfer functions; anechoic chamber radiated emissions measurements; broad frequency range; current measurements; electronic device testing; empirically-derived transfer functions; field measurements; laboratory common-mode current measurements; nonanechoic chamber; radiated emissions measurement prediction; Anechoic chambers; Antenna measurements; Cables; Current measurement; Electric variables measurement; Fixtures; Frequency measurement; Laboratories; Testing; Transfer functions;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1998. 1998 IEEE International Symposium on
Conference_Location
Denver, CO
Print_ISBN
0-7803-5015-4
Type
conf
DOI
10.1109/ISEMC.1998.750122
Filename
750122
Link To Document