• DocumentCode
    3346290
  • Title

    Thermal performance test of U-type evacuated glass tubular solar collector filled with graphite

  • Author

    Liang, Ruobing ; Ma, Liangdong ; Zhang, Jili

  • Author_Institution
    Sch. of Civil & Hydraulic Eng., Dalian Univ. of Technol., Dalian, China
  • fYear
    2010
  • fDate
    26-28 June 2010
  • Firstpage
    4066
  • Lastpage
    4069
  • Abstract
    In this paper, a new type of U-type pile evacuated glass tubular solar collector filled with graphite has been proposed and investigated its thermal performance experimentally, and testing accuracy has been analyzed by the error analysis method. Following dynamic testing method, the outlet temperature and momentary efficiency equation of the collector were got. The results showed that, U-tubular evacuated tube has higher momentary efficiency, the outlet temperature can increase 6~7°C in test situation, the optimum flow rate of U-type evacuated tubular is 0.0028L/s.
  • Keywords
    dynamic testing; error analysis; graphite; pipes; solar absorber-convertors; U-tubular evacuated tube; U-type evacuated glass tubular solar collector; U-type evacuated tubular; dynamic testing method; error analysis method; graphite; momentary efficiency equation; outlet temperature; thermal performance test; Absorption; Error analysis; Glass; Heat transfer; Solar heating; Solar radiation; Temperature; Testing; Thermal conductivity; Thermal engineering; U-type evacuated glass tubular; filled with graphite; solar collector; thermal performance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanic Automation and Control Engineering (MACE), 2010 International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-7737-1
  • Type

    conf

  • DOI
    10.1109/MACE.2010.5535436
  • Filename
    5535436