DocumentCode :
334944
Title :
1 nA beam position monitoring system
Author :
Ursic, Rok ; Flood, Roger ; Piller, Chip ; Strong, Edward ; Turlington, Larry
Author_Institution :
Thomas Jefferson Nat. Accel. Facility, Newport News, VA, USA
Volume :
2
fYear :
1997
fDate :
12-16 May 1997
Firstpage :
2131
Abstract :
A system has been developed at Jefferson Lab for measuring transverse position of very low current beams delivered to the Experimental Hall B of the Continuous Electron Beam Accelerator Facility (CEBAF). At the heart of the system is a position sensitive cavity operating at 1497 MHz. The cavity utilizes a unique design which achieves a high sensitivity to beam position at relatively low cavity Q. The cavity output RF signal is processed using a down-converter and a commercial lock-in amplifier operating at 100 kHz. The system interfaces with a VME based EPICS control system using the IEEE 488 bus. The main features of the system are simple and robust design, and wide dynamic range capable of handling beam currents from 1 nA to 1000 nA with an expected resolution better than 100 μm. This paper outlines the design of the system
Keywords :
accelerator cavities; accelerator control systems; electron accelerators; linear colliders; particle beam diagnostics; 1 to 1000 nA; 1497 kHz; CEBAF; Continuous Electron Beam Accelerator Facility; beam currents; beam position monitoring system; cavity output RF signal; commercial lock-in amplifier; position sensitive cavity; transverse position; very low current beams; Control systems; Current measurement; Electron accelerators; Electron beams; Heart; Monitoring; Particle beams; Position measurement; Radiofrequency amplifiers; Signal design;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
Type :
conf
DOI :
10.1109/PAC.1997.751131
Filename :
751131
Link To Document :
بازگشت