DocumentCode
334947
Title
The closed orbit measuring system at the DELTA synchrotron radiation facility
Author
Jankowiak, A. ; Wille, K.
Author_Institution
Inst. for Accel. Phys. & Synchrotron Radiat., Dortmund Univ., Germany
Volume
2
fYear
1997
fDate
12-16 May 1997
Firstpage
2140
Abstract
This paper presents the closed orbit measuring system of the DELTA SR Facility, concerning the hardware set-up, data processing and the calibration methods. The results of the calibration measurements and the recent operating experiences will be discussed. These results show, that the BPM offsets with respect to the magnetic centre of the quadrupole magnets turn out to be not acceptable. Therefore it was decided to install a beam based BPM calibration system in the near future
Keywords
electron accelerators; particle beam diagnostics; storage rings; synchrotrons; DELTA SR Facility; DELTA synchrotron radiation facility; calibration; closed orbit measuring system; data processing; quadrupole magnets; Calibration; Data processing; Electronic equipment testing; Extraterrestrial measurements; Frequency; Hardware; Local oscillators; Magnetic heads; Particle beams; Synchrotron radiation;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location
Vancouver, BC
Print_ISBN
0-7803-4376-X
Type
conf
DOI
10.1109/PAC.1997.751134
Filename
751134
Link To Document