Title :
Performance of the single-pass position monitor at SOR-RING
Author :
Kudo, Hiroyuki ; Koseki, Takafumi ; Nakamura, N. ; Kamiya, Yushi ; Honda, Taiki
Author_Institution :
Inst. for Solid State Phys., Tokyo Univ.
Abstract :
The R&D of single-pass beam position monitor is being carried out at SOR-RING, a 500-MeV electron storage ring. The bunch signals from four button electrodes are directly fed into a 4-channel digital oscilloscope through semi-rigid cables. The digitized data are sent to a workstation for the beam position calculation. The relative accuracy much less than 0.1 mm has been obtained with this system
Keywords :
electron accelerators; particle beam diagnostics; storage rings; 500 MeV; SOR-RING; button electrodes; electron storage ring; single-pass beam position monitor; single-pass position monitor; Cables; Electrodes; Electron beams; Monitoring; Oscilloscopes; Position measurement; Production facilities; Storage rings; Structural beams; Synchrotron radiation;
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
DOI :
10.1109/PAC.1997.751136