Title :
Beam profile monitors in the NLCTA
Author :
Nantista, C. ; Adolphsen, C. ; Brown, R.L. ; Fuller, R. ; Rifkin, J.
Author_Institution :
Linear Accel. Center, Stanford Univ., CA, USA
Abstract :
The transverse current profile in the Next Linear Collider Test Accelerator (NLCTA) electron beam can be monitored at several locations along the beam line by means of profile monitors. These consist of insertable phosphor screens, light collection and transport systems, CID cameras, a frame-grabber, and PC and VAX based image analysis software. In addition to their usefulness in tuning and steering the accelerator, the profile monitors are utilized for emittance measurement. A description of these systems and their performance is presented
Keywords :
electron accelerators; high energy physics instrumentation computing; linear colliders; particle beam diagnostics; CID cameras; NLCTA; Next Linear Collider Test Accelerator; PC based image analysis software; VAX based image analysis software; beam profile monitors; emittance measurement; frame-grabber; insertable phosphor screens; light collection and transport systems; transverse current profile; Colliding beam accelerators; Colliding beam devices; Electron accelerators; Electron beams; Life estimation; Linear accelerators; Monitoring; Particle beams; Phosphors; Testing;
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
DOI :
10.1109/PAC.1997.751150