• DocumentCode
    335014
  • Title

    Beam test of the acceleration system with the DDS in HIMAC synchrotron

  • Author

    Kanazawa, M. ; Noda, K. ; Takada, E. ; Kumada, M. ; Itano, A. ; Watanab, S. ; Morii, Y.

  • Author_Institution
    Nat. Inst. of Radiol. Sci., Chiba, Japan
  • Volume
    2
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    2347
  • Abstract
    We have examined the acceleration efficiency as a function of B-clock step size from 0.1 to 2.0 Gauss/pulse at the HIMAC synchrotron. The result showed good acceleration efficiency with 0.2 Gauss/pulse, even if we haven´t used feedback. The larger width case shows significant loss, suggesting a limitation due to stepwise change of acceleration frequency
  • Keywords
    beam handling equipment; ion accelerators; synchrotrons; B-clock step size; HIMAC; acceleration efficiency; acceleration frequency; acceleration system; direct digital synthesizer; synchrotron; Acceleration; Clocks; Frequency; Gaussian processes; Life estimation; Particle beams; Switches; Synchrotrons; System testing; Voltage-controlled oscillators;