Title :
A Trigger System based on fast sampling ADCs - implementation and tests
Author :
Marciniewski, P. ; Plucinski, P. ; Fransson, K. ; Heijkenskojld, L. ; Kupsc, A. ; Zlomanczuk, J. ; Wolke, M. ; Calen, H. ; Johansson, T. ; Hoistad, B. ; Erven, W. ; Wuestner, P. ; Kleines, H. ; Hejny, V. ; Coderre, D.
Author_Institution :
Inst for Phys. & Astron., Uppsala Univ., Uppsala, Sweden
Abstract :
A Trigger System for a multi-detector setup is presented. The system takes advantage of the newly developed continuous-sampling 16-channel, 12-bit, 160-Msps ADC modules. The ADCs are equipped with programmable logic (FPGA) and perform on-line digital “charge” integration, resolve pile-ups and compute arrival times of detector signals with an accuracy of 1.5 ns. A fast trigger data lane connects the ADC units to a Trigger Module using optical links. Each Trigger Module features 16 optical interfaces (SFP) running at 2 Gb/s input data rate and can be used for evaluating trigger decisions or as a DAQ unit. The Trigger system was implemented in the WASA@COSY experiment, performing on-line event reconstruction, including complex detector calibration, delivering triggers based on multiplicity of tracks fulfilling deposited energy, scattering angle and ΔE/E criteria. Depending on the trigger algorithm used, the trigger latency measured from the actual detector signal to the trigger output amounts to 1.3 - 1.5 μs.
Keywords :
analogue-digital conversion; calibration; data acquisition; field programmable gate arrays; high energy physics instrumentation computing; nuclear electronics; solid scintillation detectors; trigger circuits; DAQ system; FPGA; complex detector calibration; continuous-sampling ADC module; fast sampling ADC system; fast trigger data lane; input data rate; multidetector setup; on-line digital charge integration process; on-line event reconstruction method; optical links; plastic scintillator detector; time 1.5 ns; trigger algorithm; trigger system; Boolean functions; Data structures; Europe; Optical devices; Optical fiber communication;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
Print_ISBN :
978-1-4673-0118-3
DOI :
10.1109/NSSMIC.2011.6154359