Title :
On combining off-line BIST and on-line control flow checking
Author_Institution :
Elektrotech. und Inf., Univ.-GH-Siegen, Germany
Abstract :
If offline testing is complemented by online checks, in general some of the test hardware is only used either for online checking or for testing. A novel target structure for self-testable and self-monitoring controllers is presented, and a formal framework for the synthesis of self-monitoring controllers is established. It combines a method of monitoring the control flow with a self-test structure in such a way, that the self-test hardware is utilized for facilitating control flow checking. The corresponding design procedure considers this target structure while synthesizing the controller from a behavioral description, and thus minimizes hardware overheads. Existing approaches for designing concurrently checked controllers can be represented as special cases in the formal framework established. Experimental results are summarized.<>
Keywords :
built-in self test; logic testing; formal framework; off-line BIST; on-line control flow checking; self-monitoring controllers; self-testable; target structure; Automatic testing; Built-in self-test; Circuit faults; Circuit testing; Error correction; Hardware; Monitoring; Registers; Runtime; Test pattern generators;
Conference_Titel :
Fault-Tolerant Computing, 1992. FTCS-22. Digest of Papers., Twenty-Second International Symposium on
Conference_Location :
Boston, MA, USA
Print_ISBN :
0-8186-2875-8
DOI :
10.1109/FTCS.1992.243571