Space charge distribution measured with short period interval up to electrical breakdown in polyethylene
Author
Mitsumoto, Shin´ichi ; Tanaka, Keny ; Muramoto, Yuji ; Nagao, Masayuki ; Hozumi, Naohiro ; Fukuma, Masumi
Author_Institution
Dept. of Electr. Eng., Ube Nat. Coll. of Technol., Japan
Volume
2
fYear
1999
fDate
1999
Firstpage
634
Abstract
The paper describes the space charge behavior measured with short period interval up to electrical breakdown in polyethylene film. Positive space charge was formed from the anode near the opposite electrode within 1.2 seconds after voltage application of 30 kV in a HDPE film. Up to electrical breakdown, this positive space charge formulation did not change. From this result, it is considered that there is the possibility that electrical breakdown in HDPE film is caused by hetero space charge, which enhances the cathode field just before electrical breakdown. The amount of homo space charge accumulation near both electrodes increased with time of voltage application in the LDPE film. Space charge distribution was remarkably changed with time. Electrical breakdown occurred when the negative space charge layer reached the cathode after hetero space charge was formed in the bulk. There is a possibility that hetero space charge formation may be a pre-breakdown phenomena in LDPE films
Keywords
electric breakdown; polyethylene insulation; polymer films; power cable insulation; space charge; electrical breakdown; hetero space charge; homo space charge accumulation; polyethylene film; short period interval; space charge distribution; Cathodes; Charge measurement; Current measurement; Electric breakdown; Electric variables measurement; Electrodes; Plastic films; Polyethylene; Space charge; Voltage;
fLanguage