Abstract :
Four reinforced concrete shear walls were loaded to normal section failure under the cyclic reverse loads. Then the reinforcement method was researched based on the failure mode. The composite reinforcement method of replacing damaged concrete and bonding carbon fiber sheet was adopted. The reverse loads were exerted on the four damaged reinforced concrete shear walls strengthened with carbon fiber sheet until the walls failed. By analyzing the experimental data, the recovery degrees of normal section bearing capacity were discussed. Test results indicate that the normal section bearing capacities of shear walls reached that of original walls.
Keywords :
carbon fibre reinforced composites; reinforced concrete; shear strength; sheet materials; bonding carbon fiber sheet; cyclic reverse loads; damaged concrete; failure mode; normal section failure; reinforced concrete shear wall; reinforcement method; section bearing capacity; Civil engineering; Concrete; Educational institutions; Fasteners; Hydraulic actuators; Lifting equipment; Optical fiber testing; Servomechanisms; Steel; Structural beams; carbon fiber sheet; flexural capacity; reinforcement; shear wall;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Mechanic Automation and Control Engineering (MACE), 2010 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-7737-1
Type :
conf
DOI :
10.1109/MACE.2010.5535994
Filename :
5535994
Link To Document :
بازگشت