DocumentCode
335539
Title
A pulsed ion source for the IUCF Cooler Injector Synchrotron
Author
Derenchuk, V.P. ; Kupper, R.R. ; Petri, H.R. ; Berg, G.P.A. ; Brown, R.J. ; Fox, W.R. ; Friesel, D.L. ; Hunt, W. ; Jones, W.P. ; Lozowski, W.R.
Author_Institution
Cyclotron Facility, Indiana Univ., Bloomington, IN, USA
Volume
3
fYear
1997
fDate
12-16 May 1997
Firstpage
2737
Abstract
A pulsed source of H- ions has been constructed with minimal cost and is currently being used for commissioning of the Indiana University Cyclotron Facility (IUCF) Cooler Injector Synchrotron. A commercially available duoplasmatron, previously used with the IUCF cyclotrons, was modified for pulsed operation and has produced 25 keV H- ion beams of up to 1 mA in an emittance of less than 0.38 π-mm-mrad normalized (80%) and can operate up to 10 Hz with 50 μs to 4 ms pulse length. A simple and economical pulsed high-power MOSFET circuit is used to drive the arc and the gas valve. The beam transport line to the 7 MeV RFQ-DTL, features an Einzel lens doublet immediately upstream to match the beam from the source. The design, development and performance of the ion source and beam transport line is presented
Keywords
duoplasmatrons; ion beams; particle beam diagnostics; 25 keV; Cooler Injector Synchrotron; Einzel lens doublet; H- source; IUCF; MOSFET circuit; RFQ-DTL; beam transport line; duoplasmatron; emittance; pulsed ion source; Apertures; Costs; Cyclotrons; Fuels; Ion beams; Ion sources; Lenses; Pulse circuits; Synchrotrons; Valves;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location
Vancouver, BC
Print_ISBN
0-7803-4376-X
Type
conf
DOI
10.1109/PAC.1997.752749
Filename
752749
Link To Document