Title : 
Performance of Separated Heat Pipe Heated by Hot Water
         
        
            Author : 
Zhou Jie ; Han Wei Shi
         
        
            Author_Institution : 
Coll. of Nucl. Sci. & Technol., Harbin Eng. Univ., Harbin
         
        
        
        
        
        
            Abstract : 
The separated heat pipe (SHP) has a very good heat transfer capacity, and it can transfer heat through long distance, so it is appropriate to use it as heat transfer of nuclear reactor. It can be used as heat transfer in pressurized water reactor (PWR). This paper is concerned with the starting capacity, uniform temperature capacity, efficiency of SHP and its mode of transferring heat under the condition of water bath.
         
        
            Keywords : 
heat pipes; heat transfer; light water reactors; heat transfer capacity; hot water; pressurized water reactor; separated heat pipe; starting capacity; uniform temperature capacity; Educational institutions; Heat engines; Heat transfer; Inductors; Nuclear and plasma sciences; Resistance heating; Safety; Steel; Temperature; Water heating;
         
        
        
        
            Conference_Titel : 
Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
         
        
            Conference_Location : 
Wuhan
         
        
            Print_ISBN : 
978-1-4244-2486-3
         
        
            Electronic_ISBN : 
978-1-4244-2487-0
         
        
        
            DOI : 
10.1109/APPEEC.2009.4918593