• DocumentCode
    3358560
  • Title

    Characterization of Al-Schottky CdTe detectors

  • Author

    Abbene, L. ; Gerardi, G. ; Principato, F. ; Turturici, A.A. ; Del Sordo, S. ; Raso, G.

  • Author_Institution
    Dipt. di Fis. (DIFI), Univ. di Palermo, Palermo, Italy
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    4636
  • Lastpage
    4641
  • Abstract
    In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25°C under a bias voltage of -100 V for the 2 mm thick detector). Polarization phenomena, typical of CdTe diode detectors, were investigated through electrical and spectroscopic approaches, pointing out the influence of the bias voltage, the temperature and the detector thickness. Good time stability, during a short-term operation of one hour, was observed for both detectors at temperatures below 10°C and by using an electric field of 5000 V/cm. The detectors exhibited good energy resolution of 1.5 keV (FWHM) at 59.5 keV (T=-25°C) by using a standard electronic chain. This work was carried out in the framework of the development of portable X-ray spectrometers for both laboratory research and medical applications.
  • Keywords
    Schottky diodes; X-ray spectrometers; X-ray spectroscopy; semiconductor counters; Al-Schottky CdTe detectors; Au-Ti-Al-CdTe-Pt electrode configuration; Schottky CdTe diode detectors; anode pixellization; electric field; electrical investigation; electron volt energy 1.5 feV; gamma ray spectroscopy; high resolution X-ray spectroscopy; laboratory research; low leakage currents; medical applications; polarization phenomena; portable X-ray spectrometers; spectroscopic investigation; standard electronic chain; Anodes; Biomedical imaging; Extraterrestrial measurements; Gold; Lead; CdTe; X-ray and gamma ray spectroscopy; diode detectors; polarization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6154749
  • Filename