Title :
Radially and longitudinally water block cable utilizing a corrugated, longitudinally folded and sealed copper tape
Author :
Cinquemani, P.L. ; Kuchta, F.L.
Author_Institution :
Pirelli Cables & Syst. North America, Lexington, SC, USA
Abstract :
It is well known that the life of an extruded dielectric cable can deteriorate more rapidly under AC voltage stress when moisture is present in the insulation. There are many mechanisms that may subject the insulation system of a cable to moisture during the cable´s life. This paper reviews a novel design that is radially and longitudinally water blocked a new test method for radial water tightness and the most typical test results. The basic design concept includes a filled conductor, extruded polymeric insulation system, longitudinal moisture barrier, a combination metallic shield/radial moisture barrier and an overall jacket
Keywords :
insulation testing; leak detection; life testing; moisture; power cable insulation; power cable testing; underground cables; underground residential distribution systems; AC voltage stress; URD power cable insulation; cable jacket; combination metallic shield/radial moisture barrier; design concept; extruded dielectric insulation life; extruded polymeric insulation system; filled conductor; longitudinal moisture barrier; moisture; radial water tightness testing; Cable insulation; Cable shielding; Conductors; Dielectrics and electrical insulation; Moisture; Plastic insulation; Polymers; Stress; Testing; Voltage;