    Configuring an electrostatic membrane reflector with potentials exerted on distributed electrodes

  • Author

    Shi, Guangfeng ; Zhong, Xing ; Jin, Guang ; Zhang, Pen

  • Author_Institution
    Changchun Inst. of Opt., Fine Mech. & Phys., Chinese Acad. of Sci., Changchun, China
  • fYear
    2009
  • fDate
    9-12 Aug. 2009
  • Firstpage
    5089
  • Lastpage
    5093
  • Abstract
    Electrostatic membrane reflector (EMR) is very promised for optical quality application with the merits of ultra-lightweight and flexible. Configuring a circular membrane reflector with electrostatic potentials exerted on distributed electrodes can approximatively produce a parabolic shape. A 300 mm EMR (made from polyimide) stretched by distributed electrodes below is designed, and the number of concentric electrodes needed for membrane shape forming is analysed. First, based on an analytical solution of Poisson´s equation, determine the membrane control matrix by finding influence functions of 3 concentric electrodes and 6 control points on membrane surface in order to compute the needed voltages exerted on the distributed electrodes by the method of least-squares fitting. Then the final shape solved by finite element analysis with ANSYS is contrasted with the paraboloid and deviates greatly when the central displacement of membrane is beyond 2.5 mm, but in this range increasing the number of electrodes and control points will get a better shape. The corresponding errors are analyzed, and the control method is concluded. Only using the integrated method of analytical computation, numerical analysis and experiment, the membrane shape of certain central displacement can be exactly predicted and controlled.
  • Keywords
    Poisson equation; electrodes; electrostatic devices; error analysis; finite element analysis; least squares approximations; optical elements; shape control; ANSYS; Poisson equation; analytical computation; analytical solution; central displacement; concentric electrodes; control method; control points; distributed electrodes; electrostatic membrane reflector; electrostatic potentials; error analysis; finite element analysis; integrated method; least-square fitting; membrane control matrix; membrane shape forming; membrane surface; numerical analysis; optical quality application; polyimide; size 300 mm; Biomembranes; Centralized control; Displacement control; Electrodes; Electrostatics; Poisson equations; Polyimides; Shape control; Surface fitting; Voltage control; Control matrix; Electrode; Electrostatic; Least-squares fitting; Membrane reflector;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronics and Automation, 2009. ICMA 2009. International Conference on
  • Conference_Location
    Changchun
  • Print_ISBN
    978-1-4244-2692-8
  • Electronic_ISBN
    978-1-4244-2693-5
  • Type

    conf

  • DOI
    10.1109/ICMA.2009.5246143
  • Filename
    5246143