• DocumentCode
    3363978
  • Title

    Compression of diagnostic resting electrocardiograms

  • Author

    Zywietz, Chr ; Joseph, G. ; Fischer, R.

  • Author_Institution
    Biosignalverarbeitung, Medizinische, Hanover, Germany
  • fYear
    1990
  • fDate
    23-26 Sep 1990
  • Firstpage
    391
  • Lastpage
    394
  • Abstract
    dA new scheme for the reduction of resting electrocardiograms (ECGs) is designed. A representative cycle is computed from the resting ECG record. This cycle, sampled at 500S/s and with amplitude quantization of 5 μV/LSB is compressed by redundancy reduction. The representative cycle is subtracted from the original record at all complex locations. The remaining data-the residual-can then be compressed by the reduction of sampling rate, coarsed amplitude quantization and Huffman encoding. To preserve QRS details within reconstructed records the respective data sections are only redundancy reduced. By means of the new method compression ratios of 10-30 are obtained
  • Keywords
    data compression; electrocardiography; ECG compression; Huffman encoding; QRS details; coarsed amplitude quantization; compression ratio; data sections; diagnostic resting electrocardiograms; redundancy; redundancy reduction; sampling rate; Communication standards; Data compression; Electrocardiography; Encoding; Information retrieval; Inspection; Protocols; Quantization; Redundancy; Sampling methods;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology 1990, Proceedings.
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    0-8186-2225-3
  • Type

    conf

  • DOI
    10.1109/CIC.1990.144241
  • Filename
    144241