DocumentCode
3364887
Title
Variations in temperature and performance in a standard and thermally bridged compact fluorescent fixture
Author
Sgro, Lee Anne ; Siminovitch, Michael
Author_Institution
Lawrence Berkeley Lab., CA, USA
fYear
1992
fDate
4-9 Oct 1992
Firstpage
1880
Abstract
The spatial temperature distribution in an enclosed, screw base, 13 W compact fluorescent retrofit fixture and the surrounding environment was investigated for a typical recessed fixture application. The minimum lamp wall temperature and light output were measured over time with and without a thermal bridging system. The experimental data were used to design an efficient thermal bridge and to evaluate the performance of the bridge, which was found to increase the relative light output of the fixture of about 20%
Keywords
fluorescent lamps; testing; thermal analysis; 13 W; compact fluorescent lamps; design; lamp wall temperature; performance; spatial temperature distribution; testing; thermal analysis; thermal bridging system; Bridges; Electronic ballasts; Fasteners; Fixtures; Fluorescence; Fluorescent lamps; Temperature distribution; Temperature measurement; Thermistors; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting, 1992., Conference Record of the 1992 IEEE
Conference_Location
Houston, TX
Print_ISBN
0-7803-0635-X
Type
conf
DOI
10.1109/IAS.1992.244549
Filename
244549
Link To Document