• DocumentCode
    3364887
  • Title

    Variations in temperature and performance in a standard and thermally bridged compact fluorescent fixture

  • Author

    Sgro, Lee Anne ; Siminovitch, Michael

  • Author_Institution
    Lawrence Berkeley Lab., CA, USA
  • fYear
    1992
  • fDate
    4-9 Oct 1992
  • Firstpage
    1880
  • Abstract
    The spatial temperature distribution in an enclosed, screw base, 13 W compact fluorescent retrofit fixture and the surrounding environment was investigated for a typical recessed fixture application. The minimum lamp wall temperature and light output were measured over time with and without a thermal bridging system. The experimental data were used to design an efficient thermal bridge and to evaluate the performance of the bridge, which was found to increase the relative light output of the fixture of about 20%
  • Keywords
    fluorescent lamps; testing; thermal analysis; 13 W; compact fluorescent lamps; design; lamp wall temperature; performance; spatial temperature distribution; testing; thermal analysis; thermal bridging system; Bridges; Electronic ballasts; Fasteners; Fixtures; Fluorescence; Fluorescent lamps; Temperature distribution; Temperature measurement; Thermistors; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 1992., Conference Record of the 1992 IEEE
  • Conference_Location
    Houston, TX
  • Print_ISBN
    0-7803-0635-X
  • Type

    conf

  • DOI
    10.1109/IAS.1992.244549
  • Filename
    244549