DocumentCode :
3366917
Title :
Pilot-scale study of efficient coagulation sedimentation of micro-polluted water
Author :
Shen, Liang ; Cheng, Li ; Wang, Heli ; Lian, Xinying ; Qi, Jingxian
Author_Institution :
Sch. of Water Resource & Environ., China Univ. of Geosci.(Beijing), Beijing, China
fYear :
2010
fDate :
2-4 Nov. 2010
Firstpage :
124
Lastpage :
127
Abstract :
This pilot-scale study is based on an efficient coagulation sedimentation process technology used for micro-polluted water treatment of Beijing-Hangzhou Grand Canal(BHGC). The best coagulant among PAC, Al2(SO4)3 and FeCl3 and its optimal dosage were studied in coagulation sedimentation jar test. The best coagulant was PAC, and its optimal dosage was 40 mg/L. The coagulation sedimentation jar test showed that the organic removal rate could be affected by pH value definitely, and using the PAC as coagulant, water temperature had less impact on the removal rate of turbidity. The continuous experimental operation showed that the turbidity and CODMn could be scientifically removed by the efficient coagulation sedimentation operation system.
Keywords :
coagulation; pH; river pollution; sedimentation; turbidity; water pollution control; water treatment; Beijing-Hangzhou grand canal; coagulation sedimentation process; micropolluted water treatment; organic removal; pH value; turbidity; Coagulation; Irrigation; coagulant; efficient coagulation sedimentation; micro-polluted water; pH; water temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Chemical, Biological and Environmental Engineering (ICBEE), 2010 2nd International Conference on
Conference_Location :
Cairo
Print_ISBN :
978-1-4244-8748-6
Electronic_ISBN :
978-1-4244-8749-3
Type :
conf
DOI :
10.1109/ICBEE.2010.5653560