DocumentCode :
3369169
Title :
Operation and Performance of the First High Current LTD at Sandia National Laboratories
Author :
Rogowski, S.T. ; Fowler, W.E. ; Mazarakis, M. ; Olson, C.L. ; McDaniel, D. ; Struve, K.W. ; Sharpe, R.A.
Author_Institution :
Sandia Nat. Labs., Albuquerque, NM
fYear :
2005
fDate :
13-17 June 2005
Firstpage :
155
Lastpage :
157
Abstract :
A High Current Liner Transformer Driver (LTD) laboratory is operating at Sandia National Laboratories with an LTD/100 cavity running in rep-rate mode. With over one thousand shots completed the output of the LTD/100 is in excellent agreement with circuit model, SCREAMER [1] simulations, and exceeding the original operating predictions. Operating at a rep-rate of 1/30 Hz and a charge voltage of 85 kV, the LTD/100 is achieving a mean peak current of 514.6 kA plusmn 4.8 kA with a rise time of 60.6 ns plusmn 1.7 ns. With improvements to the support systems of the LTD/100 cavity it will be feasible to achieve a rep-rate of 1/15 Hz or less. The high current, short pulse capabilities combined with good reliability shows that LTD technology is a great candidate for use in future pulsed power applications.
Keywords :
power transformers; pulsed power technology; SCREAMER; linear transformer driver; pulsed power applications; rep-rate mode; voltage 85 kV; Assembly; Capacitors; Circuit simulation; Circuit testing; Contracts; Iron; Laboratories; Low voltage; Predictive models; Switches;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 2005 IEEE
Conference_Location :
Monterey, CA
Print_ISBN :
0-7803-9189-6
Electronic_ISBN :
0-7803-9190-x
Type :
conf
DOI :
10.1109/PPC.2005.300530
Filename :
4084175
Link To Document :
بازگشت