DocumentCode
3369488
Title
Experimental ESD method for restoration of blurry image in ultrasonic C-Scan
Author
Kong, Tao ; Xu, Chunguang ; Xiao, Dingguo
Author_Institution
Sch. of Mech. Eng., Beijing Inst. of Technol., Beijing, China
fYear
2010
fDate
26-28 June 2010
Firstpage
2632
Lastpage
2635
Abstract
A 2-D Deconvolution method for the improvement of ultrasonic defocused C-scan images is presented by using experimental Edge Spread Distribution (ESD) of transducer. In the paper, experiments corresponding different imaging depth were implemented to establish a relation of the ESD and blurry C-scan images. Based on the relationship of ESD and line response, the Point Spread Function (PSF), as the core function of deconvolution, can be obtained from line response by Abel transform. The results show that this deconvolution method is efficient and it is feasible to deblur the defocused C-scan images.
Keywords
deconvolution; image restoration; transforms; ultrasonic imaging; 2D deconvolution method; Abel transform; blurry image restoration; edge spread distribution; experimental ESD method; point spread function; transducer; ultrasonic C-Scan images; Deconvolution; Electrostatic discharge; Focusing; Hardware; Image resolution; Image restoration; Mechanical engineering; Signal processing; Ultrasonic imaging; Ultrasonic transducers; Edge Spread Distribution; PSF; blurring; deconvolution; ultrasonic C-scan;
fLanguage
English
Publisher
ieee
Conference_Titel
Mechanic Automation and Control Engineering (MACE), 2010 International Conference on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-7737-1
Type
conf
DOI
10.1109/MACE.2010.5536806
Filename
5536806
Link To Document