Abstract :
The eddy current (EC) loss is analyzed in the isolation shell (IS) of axial permanent magnet coupling (PMC). The eddy current caused by the variational magnetic field makes the magnets temperature increase and the magnet performance degrade, reducing transmission efficiency of Permanent Magnet Coupling(PMC). Distribution of the magnetic flux density in the magnetic gap is determined by the equivalent current method and EC loss is analyzed by using the magnetic flux density. The calculation shows that EC loss would decrease with the relative angle between the driving and the driven magnets increasing. The loss would increase with the thickness and conductivity of IS increasing. An expression for the engineers to estimate average EC loss is given by the factor analysis.
Keywords :
eddy current losses; electrical conductivity; magnetic flux; permanent magnets; EC loss; axial permanent magnet coupling; conductivity; eddy current loss; equivalent current method; isolation shell; magnetic flux density; magnetic gap; transmission efficiency; variational magnetic field; Conductivity; Couplings; Degradation; Eddy currents; Magnetic analysis; Magnetic fields; Magnetic flux; Magnetic flux density; Permanent magnets; Temperature; Coupling; Eddy current; Loss; Permanent magnet;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Mechatronics and Automation, 2009. ICMA 2009. International Conference on
Conference_Location :
Changchun
Print_ISBN :
978-1-4244-2692-8
Electronic_ISBN :
978-1-4244-2693-5
Type :
conf
DOI :
10.1109/ICMA.2009.5246649
Filename :
5246649
Link To Document :
بازگشت