• DocumentCode
    337252
  • Title

    Telemetry system of daily life motion and arrhythmia

  • Author

    Kobayashi, Ikuo ; Hayashi, Ressei ; Sugawara, Akihiko ; Matsumoto, Hiroshi

  • Author_Institution
    Signalysis Inc., Saitama, Japan
  • Volume
    5
  • fYear
    1997
  • fDate
    1997
  • Firstpage
    2229
  • Abstract
    An ambulatory electrocardiogram (ECG) recording system have been used to record cardiac arrhythmia in daily life. The system can continuously record the ECG waveform so that physicians could diagnose the cardiac disease, together with event recordings which can also provide the recording of activity of daily life (ADL), such as standing, walking, or eating. Patients, however, often forget to record the events. Our first approach to record ADL was AC-100 (GMS Co. Ltd.), which can record the zero-crossing count of three dimensional accelerometer outputs and RR intervals. We have been revised the instrument to make AC-4X, which can transmit an ECG signal, and acceleration wave signals. The signal received by the analyzing host computer is processed with finite impulse response (FIR) filters, and some other real-time filters. Also, the state transition charts and tables are used to recognize the output of filters. ECG signal is recognized by algorithm to indicate some types of arrhythmia, and acceleration signals are recognized to indicate some motion of daily life. The effort is on going to cover as many subjects as possible
  • Keywords
    FIR filters; acceleration measurement; biomedical telemetry; electrocardiography; gait analysis; medical signal processing; motion measurement; patient monitoring; 3D accelerometer outputs; RR intervals; ambulatory ECG recording system; cardiac arrhythmia; daily life motion; eating; event recordings; finite impulse response filters; gait analysis; motion recognition; protocol machine; real-time filters; signal recognition logic; standing; state transition charts; telemetry system; walking; zero-crossing count; Acceleration; Accelerometers; Cardiac disease; Electrocardiography; Finite impulse response filter; Instruments; Legged locomotion; Signal analysis; Signal processing; Telemetry;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-4262-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.1997.758802
  • Filename
    758802