• DocumentCode
    3372766
  • Title

    A temperature control solution applied to IC failure analysis at low temperature

  • Author

    Li, Jinglong ; Liu, Jonathon

  • Author_Institution
    Product Anal. Lab., Freescale Semicond.(China) Ltd., Tianjin, China
  • fYear
    2012
  • fDate
    2-6 July 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Sometimes Failure Analysis(FA) Lab could receive a request for IC failure analysis at low temperature. However, there are some problems to get low temperature atmosphere for FA. For example, the thermo stream machine which is used in Test process is not fit to FA, especially after de-capsulation. Liquid nitrogen is usually as a common method. But it is forbidden by a local policy. To solve the problems permanently, a temperature control solution has been designed for the IC function/parameter FA at high/low temperature. The solution is based on a thermoelectric (TE) module as core part. So that not only high temperature, but also low temperature is obtained. The prototype system has been built, tested and evaluated. And a real FA case has been analyzed at low temperature based on the solution.
  • Keywords
    integrated circuit testing; temperature control; thermoelectricity; IC failure analysis; decapsulation; liquid nitrogen; low temperature atmosphere; temperature control solution; thermo stream machine; thermoelectric module; Cooling; Heat transfer; Heating; Microscopy; Nitrogen; Temperature sensors; FA; Low Temperature; Thermoelectric;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits (IPFA), 2012 19th IEEE International Symposium on the
  • Conference_Location
    Singapore
  • ISSN
    1946-1542
  • Print_ISBN
    978-1-4673-0980-6
  • Type

    conf

  • DOI
    10.1109/IPFA.2012.6306267
  • Filename
    6306267