DocumentCode
3372766
Title
A temperature control solution applied to IC failure analysis at low temperature
Author
Li, Jinglong ; Liu, Jonathon
Author_Institution
Product Anal. Lab., Freescale Semicond.(China) Ltd., Tianjin, China
fYear
2012
fDate
2-6 July 2012
Firstpage
1
Lastpage
4
Abstract
Sometimes Failure Analysis(FA) Lab could receive a request for IC failure analysis at low temperature. However, there are some problems to get low temperature atmosphere for FA. For example, the thermo stream machine which is used in Test process is not fit to FA, especially after de-capsulation. Liquid nitrogen is usually as a common method. But it is forbidden by a local policy. To solve the problems permanently, a temperature control solution has been designed for the IC function/parameter FA at high/low temperature. The solution is based on a thermoelectric (TE) module as core part. So that not only high temperature, but also low temperature is obtained. The prototype system has been built, tested and evaluated. And a real FA case has been analyzed at low temperature based on the solution.
Keywords
integrated circuit testing; temperature control; thermoelectricity; IC failure analysis; decapsulation; liquid nitrogen; low temperature atmosphere; temperature control solution; thermo stream machine; thermoelectric module; Cooling; Heat transfer; Heating; Microscopy; Nitrogen; Temperature sensors; FA; Low Temperature; Thermoelectric;
fLanguage
English
Publisher
ieee
Conference_Titel
Physical and Failure Analysis of Integrated Circuits (IPFA), 2012 19th IEEE International Symposium on the
Conference_Location
Singapore
ISSN
1946-1542
Print_ISBN
978-1-4673-0980-6
Type
conf
DOI
10.1109/IPFA.2012.6306267
Filename
6306267
Link To Document