DocumentCode
3372810
Title
Preliminary study on the EMS of CRT display for computer
Author
Xie, Da Gang ; Wu, Nan ; Yu, Jing ; Yang, Xiang Song ; Hou, Dong Yun
Author_Institution
Nat. Key Lab. of Sci. & Technol. on EMC, China Ship Dev. & Design Center, Wuhan, China
fYear
2010
fDate
20-24 Sept. 2010
Firstpage
777
Lastpage
779
Abstract
The Electromagnetic susceptibility (EMS) of cathode ray tube (CRT) display for computer was investigated preliminarily using the test method of bulk current injection (BCI). During the test, CW signals as electromagnetic interference (EMI) signals with different amplitude at a certain frequency were injected into the RGB, horizontal synchronization (HS) and vertical synchronization (VS) signal line of video graphics array (VGA) interface. Sideling stripes came into view on the CRT display when the HS signal line was injected into EMI signals. Moreover, the stronger the EMI signals, the more obvious the sideling stripes. The dependent relations between the injected signals and the coupling ones on the HS signal line were also presented.
Keywords
cathode-ray tubes; display devices; electromagnetic interference; synchronisation; CRT display; CW signals; EMS; bulk current injection; cathode ray tube display; electromagnetic interference signals; electromagnetic susceptibility; horizontal synchronization; vertical synchronization; video graphics array interface; Cathode ray tubes; Computers; Couplings; Electromagnetic interference; Electromagnetics; Medical services; Synchronization;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetics in Advanced Applications (ICEAA), 2010 International Conference on
Conference_Location
Sydney, NSW
Print_ISBN
978-1-4244-7366-3
Type
conf
DOI
10.1109/ICEAA.2010.5653927
Filename
5653927
Link To Document