• DocumentCode
    3373603
  • Title

    Comparison of valley-to-valley and peak-to-peak intervals from photoplethysmographic signals to obtain heart rate variability in the sitting position

  • Author

    Xiang Chen ; Tianjun Chen ; Feifei Luo ; Jin Li

  • Author_Institution
    Key Lab. of Biomed. Inf. Eng. of Minist. of Educ., Xi´an Jiaotong Univ., Xian, China
  • fYear
    2013
  • fDate
    16-18 Dec. 2013
  • Firstpage
    214
  • Lastpage
    218
  • Abstract
    Photoplethysmographic (PPG) signals have been considered as a promising approach to obtain heart rate variability (HRV). In the study, we used RR intervals (RRI) of electrocardiograph (ECG) as a standard to compare the accuracy of valley-to-valley intervals (VVI) and peak-to-peak intervals (PPI) from PPG for HRV analysis in the sitting position. The PPG and the ECG signals were recorded simultaneously from 20 subjects. The PPI and VVI time series were derived from the PPG signal and RRI time series were from the ECG signals. For each interval time series, 9 HRV indices were calculated. The correlation and linear regression analysis were performed to assess the consistency. The results showed that for all indices, the correlation coefficients between VVI and RRI reached 0.979±0.025 and the determination coefficients R2>0.94, which were higher than the corresponding parameters between PPI and RRI. The results suggest that for PPG signals, VVI is more reliable than PPI for HRV analysis in the sitting position.
  • Keywords
    correlation methods; electrocardiography; medical signal processing; photoplethysmography; regression analysis; time series; ECG signals; HRV analysis; HRV indices; PPG signal; PPI time series; RR intervals; RRI time series; VVI time series; correlation analysis; correlation coefficients; determination coefficients; electrocardiograph; heart rate variability; interval time series; linear regression analysis; peak-to-peak intervals; photoplethysmographic signals; sitting position; valley-to-valley intervals; Accuracy; Correlation; Educational institutions; Electrocardiography; Heart rate variability; Rail to rail inputs; Time series analysis; electrocardiography (ECG); heart rate variability (HRV); peak-to-peak intervasl(PPI); photoplethysmography (PPG); valley-to-valley intervals(VVI);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Informatics (BMEI), 2013 6th International Conference on
  • Conference_Location
    Hangzhou
  • Print_ISBN
    978-1-4799-2760-9
  • Type

    conf

  • DOI
    10.1109/BMEI.2013.6746936
  • Filename
    6746936