• DocumentCode
    3373893
  • Title

    Impact of probe configuration and calibration techniques on quality factor determination of on-wafer inductors for GHz applications

  • Author

    Havens, R.J. ; Tiemeijer, L.F. ; Garnbus, L.

  • Author_Institution
    Philips Res. Labs., Eindhoven, Netherlands
  • fYear
    2002
  • fDate
    8-11 April 2002
  • Firstpage
    19
  • Lastpage
    24
  • Abstract
    We demonstrate that the quality factors measured on on-wafer (spiral) inductor test-structures are largely influenced by the choice between ground-signal and ground-signal-ground probe configuration. In particular when the SOLT network analyzer calibration technique is used in combination with ground-signal probing, the quality factor value can be overestimated significantly.
  • Keywords
    Q-factor measurement; calibration; inductors; network analysers; probes; RF test structure; SOLT network analyzer; calibration technique; ground-signal probe configuration; ground-signal-ground probe configuration; on-wafer spiral inductor; quality factor measurement; BiCMOS integrated circuits; Calibration; Electrical resistance measurement; Impedance; Inductors; Probes; Q factor; Radio frequency; Spirals; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microelectronic Test Structures, 2002. ICMTS 2002. Proceedings of the 2002 International Conference on
  • Print_ISBN
    0-7803-7464-9
  • Type

    conf

  • DOI
    10.1109/ICMTS.2002.1193164
  • Filename
    1193164