• DocumentCode
    3375939
  • Title

    Optimization of hybrid PV/wind power system for remote telecom station

  • Author

    Paudel, Subodh ; Shrestha, J.N. ; Neto, Fernando J. ; Ferreira, Jorge A F ; Adhikari, Muna

  • Author_Institution
    Inst. of Eng., Tribhuvan Univ. (TU), Nepal
  • fYear
    2011
  • fDate
    22-24 Dec. 2011
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The rapid depletion of fossil fuel resources and environmental concerns has given awareness on generation of renewable energy resources. Among the various renewable resources, hybrid solar and wind energy seems to be promising solutions to provide reliable power supply with improved system efficiency and reduced storage requirements for stand-alone applications. This paper presents a feasibility assessment and optimum size of photovoltaic (PV) array, wind turbine and battery bank for a standalone hybrid Solar/Wind Power system (HSWPS) at remote telecom station of Nepal at Latitude (27°23\´50") and Longitude (86°44\´23") consisting a telecommunication load of Very Small Aperture Terminal (VSAT), Repeater station and Code Division Multiple Access Base Transceiver Station (CDMA 2C10 BTS). In any RES based system, the feasibility assessment is considered as the first step analysis. In this work, feasibility analysis is carried through hybrid optimization model for electric renewables (HOMER) and mathematical models were implemented in the MATLAB environment to perform the optimal configuration for a given load and a desired loss of power supply probability (LPSP) from a set of systems components with the lowest value of cost function defined in terms of reliability and levelized unit electricity cost (LUCE). The simulation results for the existing and the proposed models are compared. The simulation results shows that existing architecture consisting of 6.12 kW KC85T photovoltaic modules, 1kW H3.1 wind turbine and 1600 Ah GFM-800 battery bank have a 36.6% of unmet load during a year. On the other hand, the proposed system includes 1kW *2 H3.1 Wind turbine, 8.05 kW TSM-175DA01 photovoltaic modules and 1125 Ah T-105 battery bank with system reliability of 99.99% with a significant cost reduction as well as reliable energy production.
  • Keywords
    hybrid power systems; optimisation; photovoltaic power systems; power system economics; telecommunication power supplies; wind power; fossil fuel resources; hybrid PV/wind power system; hybrid optimization model for electric renewables; levelized unit electricity cost; loss of power supply probability; remote telecom station; renewable energy resources; repeater station and code division multiple access base transceiver station; very small aperture terminal; Feasibility Study; Hybrid PV/Wind energy system; Modeling; Optimization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Systems (ICPS), 2011 International Conference on
  • Conference_Location
    Chennai
  • Print_ISBN
    INAVLID ISBN
  • Type

    conf

  • DOI
    10.1109/ICPES.2011.6156618
  • Filename
    6156618