  • Abstract
    The goals of the thermal engineer and EMC engineer often lead to contradictory design requirements. The EMC engineer wants smaller cooling openings to provide more attenuation of electromagnetic leakage through an enclosure, while the thermal engineer wants larger openings to minimize the restriction of air flow. Previous research on perforated enclosure panels has focused mainly on their EMC performance with little thought given to how they impact the flow of cooling air. This paper addresses this deficiency by examining how the shapes and locations of the perforations also impact these two critical areas
  • Keywords
    cooling; electromagnetic compatibility; electromagnetic shielding; laminar flow; packaging; EMC engineer; EMC performance; cooling air flow; cooling openings; design requirements; electromagnetic leakage attenuation; laminar air flow; perforated enclosure panels; perforation location; perforation shapes; shielding effectiveness; thermal engineer; Apertures; Attenuation; Clocks; Cooling; Design engineering; Electromagnetic compatibility; Graphics; Silicon; Testing; Thermal engineering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1999 IEEE International Symposium on
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5057-X
  • Type

    conf

  • DOI
    10.1109/ISEMC.1999.810080
  • Filename
    810080