Title : 
A 16-Cell 80dB Dynamic-Range Auto-Ranging Read-Out Array for Uncooled IR Micro-Bolometers
         
        
            Author : 
Viarani, N. ; Liberatore, N. ; Syed, A.J. ; Gottardi, M. ; Massari, N. ; Corsi, C. ; Baschirotto, A.
         
        
            Author_Institution : 
ITC-Irst, Trento
         
        
        
        
        
        
            Abstract : 
A 0.35mum CMOS 16-cell read-out for an un-cooled VOx micro-bolometers array [1, 2] uses auto-ranging circuit to boosts the sensor dynamic-range with 19dB. Each device measures the electrical conductivity change of its sensor with respect to a common reference blind element. Before doing this, each readout channel accomplishes sequentially an automatic lOb-SAR calibration procedure, suppressing eventual sensor mismatches and drifts.
         
        
            Keywords : 
CMOS integrated circuits; bolometers; infrared detectors; microsensors; CMOS sensor interfaces; automatic 10b-SAR calibration; dynamic-range auto-ranging read-out array; electrical conductivity; readout channel; size 0.35 mum; uncooled IR micro-bolometers; uncooled infrared detectors; Bolometers; Calibration; Circuits; Infrared detectors; Infrared imaging; Infrared sensors; Packaging; Sensor arrays; Temperature sensors; Voltage; CMOS sensor interfaces; infrared sensors; micro-bolometers;
         
        
        
        
            Conference_Titel : 
Solid-State Sensors, Actuators and Microsystems Conference, 2007. TRANSDUCERS 2007. International
         
        
            Conference_Location : 
Lyon
         
        
            Print_ISBN : 
1-4244-0842-3
         
        
            Electronic_ISBN : 
1-4244-0842-3
         
        
        
            DOI : 
10.1109/SENSOR.2007.4300395