DocumentCode
3377453
Title
Measurement of emissions and immunity on telecommunication lines-a universal ISN concept for unshielded cables
Author
Stecher, Manfred
Author_Institution
Rohde & Schwarz, Munchen, Germany
Volume
2
fYear
1999
fDate
1999
Firstpage
695
Abstract
The new editions of CISPR 22/EN 55022 as well as CISPR 24/EN 55024 require testing of emission and immunity on telecommunication ports of information technology equipment (ITE) and telecommunication equipment. Different versions of impedance stabilization networks (ISNs) are required for the different conformance alternatives and cable categories. Since there is a great variety of systems with different pin connections of the Western RJ45 connector, a solution with a basic universal network using a universal interface and a series of adapters has been chosen. A high-performance balun has been developed for verification and calibration. Imperfections of the CISPR 22 standard are discussed together with characteristics and proposed amendments of CISPR 16-1 for ISN characterization and calibration
Keywords
calibration; electric connectors; electric impedance; electromagnetic interference; measurement standards; stability; telecommunication cables; telecommunication equipment testing; telecommunication transmission lines; CISPR 16-1; CISPR 22 standard; CISPR 22/EN 55022; CISPR 24/EN 55024; Western RJ45 connector; cable categories; calibration; emission measurement; high-performance balun; immunity measurement; impedance stabilization networks; information technology equipment; pin connections; telecommunication equipment; telecommunication lines; telecommunication ports; universal ISN concept; universal interface; unshielded cables; verification; Cable shielding; Calibration; DSL; Electromagnetic compatibility; Frequency; Immunity testing; Information technology; Standards publication; Telecommunication standards; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1999 IEEE International Symposium on
Conference_Location
Seattle, WA
Print_ISBN
0-7803-5057-X
Type
conf
DOI
10.1109/ISEMC.1999.810102
Filename
810102
Link To Document