Title :
A comparison of radiated emissions testing to European Directive 95/54/EC using an open field test site and a semi-anechoic chamber
Author_Institution :
Motorola AIEG, Stotfold, UK
Abstract :
Most automotive component level testing, and in particular European Directive 95/54 requires that under some (in practice most) conditions radiated emissions measurements from electrical/electronic sub-assemblies (ESAs) are made with the ESA under test mounted on an elevated ground plane 1 m high on a wooden table. It is shown that how this ground plane is connected to the test sites ground is very important, and that this is in fact a key issue in obtaining correlation between different open field sites and also in obtaining correlation to test results obtained in a semi-anechoic chamber
Keywords :
anechoic chambers (electromagnetic); correlation methods; earthing; electromagnetic interference; electronic equipment testing; measurement standards; noise measurement; European Directive 95/54/EC; automotive component level testing; commercial noise emitter; electrical/electronic sub-assemblies; elevated ground plane; measurement standards; open field test site; radiated emissions testing; semi-anechoic chamber; test results correlation; test sites ground; wooden table; Anechoic chambers; Antenna measurements; Area measurement; Frequency; Length measurement; Noise generators; Polarization; Resonance; Testing; Vehicles;
Conference_Titel :
Electromagnetic Compatibility, 1999 IEEE International Symposium on
Conference_Location :
Seattle, WA
Print_ISBN :
0-7803-5057-X
DOI :
10.1109/ISEMC.1999.810119