  • Abstract
    This paper describes work aimed at a better understanding of the sources of error in EMC tests taken in partially anechoic screened rooms. Two aspects are covered namely the characterization of screened rooms by simulation using the normalised site insertion loss, and, proximity effects on the impedance of test antennas
  • Keywords
    simulation; EMC test environments; impedance; normalised site insertion loss; partially anechoic screened rooms; proximity effects; simulation; test antennas;