• DocumentCode
    3379113
  • Title

    On the benefits of using IEEE Std 299-1997 for shielding effectiveness testing

  • Author

    Svetanoff, Dale G.

  • Author_Institution
    Lindgren RF Enclosures Inc., Glendale Heights, IL, USA
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1016
  • Abstract
    MIL-STD-285 and the origination of IEEE Std 299 go back several decades. More recent versions of Std 299 maintained technically sound test methods, but required that all frequency ranges be applied when testing enclosures. Some frequency ranges were not available for testing at all. This paper summarizes the benefits to shield owners and users that are incorporated in the current revision of Std 299. A new, menu-driven approach matches the test of shielding effectiveness to the enclosure application. Tests are no longer limited to just “high performance” enclosures, test subjects may be of any shielding material and construction, and they may be as small as 2 meters in any linear dimension
  • Keywords
    IEEE standards; electromagnetic shielding; packaging; IEEE Std 299-1997; MIL-STD-285; enclosures; menu-driven approach; shielding effectiveness testing; Acoustic testing; Building materials; Construction industry; Dynamic range; Gold; Materials testing; Performance evaluation; Radio frequency; Standards publication; USA Councils;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1999 IEEE International Symposium on
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5057-X
  • Type

    conf

  • DOI
    10.1109/ISEMC.1999.810205
  • Filename
    810205