DocumentCode :
3380297
Title :
Design of a signal processing circuit for quartz crystal microbalance biosensors
Author :
Chang, Shih-Chang ; Chao, I-Jen ; Liu, Bin-Da ; Huang, Chun-Yueh ; Lee, Mei-Hwa ; Lin, Hung-Yin
Author_Institution :
Dept. of Electr. Eng., Nat. Univ. of Tainan, Tainan, Taiwan
fYear :
2011
fDate :
25-28 Oct. 2011
Firstpage :
180
Lastpage :
183
Abstract :
In this paper, we design a signal processing circuit for quartz crystal microbalance (QCM) biosensors. The proposed signal processing circuit, which consists of two oscillators, a mixer, a low-pass filter, can be used to measure small amount of QCM biosensors´ frequency variation at a fundamental resonance frequency. Based on the principle of heterodyne technique, the QCM biosensors´ frequency variation can be converted into the low frequency composition by a second-order low-pass filter. The output of the low-pass filter is digitized to a stream of digital pulses by a simple digital buffer which represents the corresponding QCM biosensor´s frequency variation. The proposed signal processing circuit is implemented by 0.35-μm CMOS technology, and the chip layout area is 1060 mm2. In the proposed circuit, the maximum range of the detectable frequency variation is 26 kHz under the resolution of 0.5 Hz. In system verification, the proposed signal processing circuit chip is successfully applied in the signal processing of α-Amylase QCM biosensors to detect the change of low concentration biomolecular.
Keywords :
CMOS integrated circuits; biomedical electronics; biosensors; circuit resonance; integrated circuit design; low-pass filters; mixers (circuits); oscillators; quartz crystal microbalances; α-Amylase QCM biosensor; CMOS technology; chip layout area; digital buffer; digital pulses; frequency 26 kHz; frequency variation; fundamental resonance frequency; heterodyne technique; low concentration biomolecular; low frequency composition; mixer; oscillator; quartz crystal microbalance biosensor; second-order low-pass filter; signal processing circuit chip; signal processing circuit design; size 0.35 mum; system verification; Biosensors; Electric variables measurement; Frequency conversion; Frequency measurement; Linearity; Modulation; Software;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
ASIC (ASICON), 2011 IEEE 9th International Conference on
Conference_Location :
Xiamen
ISSN :
2162-7541
Print_ISBN :
978-1-61284-192-2
Electronic_ISBN :
2162-7541
Type :
conf
DOI :
10.1109/ASICON.2011.6157151
Filename :
6157151
Link To Document :
بازگشت