• DocumentCode
    3381102
  • Title

    Accurate Measurement of Active Power of Discharge Lamps

  • Author

    Fiorentin, P. ; Scroccaro, A.

  • Author_Institution
    Dept. of Electr. Eng., Univ. of Padova Via Gradenigo
  • Volume
    3
  • fYear
    2005
  • fDate
    16-19 May 2005
  • Firstpage
    1937
  • Lastpage
    1941
  • Abstract
    The active power provided to a discharge lamp appears strictly related to its luminous flux, therefore an accurate measurement of the power is required to grant stable lamp operation. A technique is presented to reach a measurement on the power with a relative uncertainty of about 0.01%. The method is based on two commercial digital multimeters with integrating analog to digital converter. The main causes of uncertainty are considered and their contributions are evaluated. The case of a 150 W sodium lamp is considered as an example
  • Keywords
    analogue-digital conversion; digital multimeters; discharge lamps; measurement uncertainty; power measurement; 150 W; active power measurement; analog to digital converter; digital multimeters; discharge lamps; luminous flux; sodium lamp; stable lamp operation; Analog-digital conversion; Current measurement; Electric variables measurement; Electronic ballasts; Frequency estimation; Lamps; Partial discharges; Power measurement; Reproducibility of results; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 2005. IMTC 2005. Proceedings of the IEEE
  • Conference_Location
    Ottawa, Ont.
  • Print_ISBN
    0-7803-8879-8
  • Type

    conf

  • DOI
    10.1109/IMTC.2005.1604509
  • Filename
    1604509