Title :
Accurate Measurement of Active Power of Discharge Lamps
Author :
Fiorentin, P. ; Scroccaro, A.
Author_Institution :
Dept. of Electr. Eng., Univ. of Padova Via Gradenigo
Abstract :
The active power provided to a discharge lamp appears strictly related to its luminous flux, therefore an accurate measurement of the power is required to grant stable lamp operation. A technique is presented to reach a measurement on the power with a relative uncertainty of about 0.01%. The method is based on two commercial digital multimeters with integrating analog to digital converter. The main causes of uncertainty are considered and their contributions are evaluated. The case of a 150 W sodium lamp is considered as an example
Keywords :
analogue-digital conversion; digital multimeters; discharge lamps; measurement uncertainty; power measurement; 150 W; active power measurement; analog to digital converter; digital multimeters; discharge lamps; luminous flux; sodium lamp; stable lamp operation; Analog-digital conversion; Current measurement; Electric variables measurement; Electronic ballasts; Frequency estimation; Lamps; Partial discharges; Power measurement; Reproducibility of results; Voltage;
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2005. IMTC 2005. Proceedings of the IEEE
Conference_Location :
Ottawa, Ont.
Print_ISBN :
0-7803-8879-8
DOI :
10.1109/IMTC.2005.1604509