    Long term isothermal reliability of copper wire bonded to thin 6.5 µm aluminum

  • Author

    Classe, F.C. ; Gaddamraja, S.

  • Author_Institution
    Spansion, Inc., Sunnyvale, CA, USA
  • fYear
    2011
  • fDate
    10-14 April 2011
  • Abstract
    In long term reliability evaluations of Spansion memory products built using copper (Cu) wire bonding in lieu of gold (Au) wire for package-to-die interconnection, results indicated acceptable reliability performance of the copper-aluminum (Cu-Al) bond. Some differences, however, were observed when compared to gold-aluminum (Au-Al) bonds used as a control. In order to determine if these differences represented a true reliability concern, a series of experiments were run on a variety of process technologies (from 200nm to 65nm) to determine wear-out failure mechanisms of these Cu bonds and their associated apparent activation energies. Isothermal reliability tests at three temperatures (150°C, 175°C, and 200°C) were performed using uncoated 0.9 mil Cu wire (with 0.9 mil Au wire as a control) bonded to functional flash die from a variety of process technologies. All bonding was done to 6.5 μm thick Aluminum-Copper (Al-0.5% Cu) bond pads. Bond shear and wire pull values were measured at each readpoint and the experiments were continued through extended long term readpoints to insure that products were stressed until failure. The primary failure mechanism identified was interfacial cracking between the copper bond and the intermetallic layer, starting at the rim of the bond. The apparent activation energy computed for the Cu-Al bond interfacial cracking was 0.70 eV. Subsequent calculations of expected product lifetime in various usage models using this Ea show that the Cu wire bonding provides more than adequate reliability lifetime for all expected product usage scenarios.
  • Keywords
    aluminium; bonding processes; copper; failure analysis; gold; reliability; wear; wires; Al; Au; Cu; Spansion memory products; bond shear; copper wire; copper-aluminum bond; electron volt energy 0.70 eV; gold-aluminum bonds; interfacial cracking; intermetallic layer; long term isothermal reliability; package-to-die interconnection; size 6.5 mum; temperature 150 C; temperature 175 C; temperature 200 C; wear-out failure mechanisms; wire pull values; Bonding; Compounds; Copper; Gold; Intermetallic; Reliability; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium (IRPS), 2011 IEEE International
  • Conference_Location
    Monterey, CA
  • ISSN
    1541-7026
  • Print_ISBN
    978-1-4244-9113-1
  • Electronic_ISBN
    1541-7026
  • Type

    conf

  • DOI
    10.1109/IRPS.2011.5784557
  • Filename
    5784557