• DocumentCode
    3383718
  • Title

    Study on Operation Oxygen Based on Efficiency and Pollutant Discharge

  • Author

    Yin, Libao ; Xu, Qisheng ; Wen, Zhiyong ; Song, Jinghui ; Zhang, Bowen ; Zhou, Liming

  • Author_Institution
    Electr. Power Res. Inst., Guangdong Power Grid Corp., Guangzhou, China
  • fYear
    2012
  • fDate
    27-29 March 2012
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    In this paper, it takes the 600MW coal-fired unit of Guangdong as the research object. On the premise of safety operation of the unit, the operation oxygen of unit is optimized and remarkable economic efficiency has been achieved. Both the economic efficiency of desulfurization system and the environmental properties of unit are included beside boiler, when compared with the traditional method, the test advances the boundary of optimized object and considers things from every angle. It might be referenced in other optimization test on the similar coal-fired generation.
  • Keywords
    electrical safety; environmental factors; optimisation; oxygen; power generation economics; steam power stations; Guangdong coal-fired unit; coal-fired generation; desulfurization system; economic efficiency; environmental properties; pollutant discharge; power 600 MW; unit operation oxygen optimisation; unit operational safety; Boilers; Carbon; Economics; Educational institutions; Fluid flow; Power systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
  • Conference_Location
    Shanghai
  • ISSN
    2157-4839
  • Print_ISBN
    978-1-4577-0545-8
  • Type

    conf

  • DOI
    10.1109/APPEEC.2012.6306902
  • Filename
    6306902