DocumentCode :
3384804
Title :
Comparison of several theoretical sub-corona to corona transition relations with recent experimental results
Author :
Danikas, M.G. ; Bruning, A.M.
Author_Institution :
SEFAG AG, Malters, Switzerland
fYear :
1992
fDate :
7-10 Jun 1992
Firstpage :
383
Lastpage :
388
Abstract :
Fast partial discharge pulse data are compared with calculated results in a continuation of previous work that attempted to model the discharge phenomenon inside enclosed cylindrical cavities. It is shown that with the present electrode arrangement, the process in the enclosed cavities is a streamer. The classical capacitor model, the recent Pedersen model, and Paschen´s law onset results are compared to the data. The preliminary thermal model is also considered. Pedersen´s model gives results closer to experimental data then the simplistic capacitor model. The streamer model corresponds with Paschen´s onset expression over a limited range, although there is no deterministic relation
Keywords :
corona; insulation testing; partial discharges; Paschen´s law onset; Pedersen model; classical capacitor model; enclosed cylindrical cavities; fast PD pulse data; streamer model; sub-corona to corona transition relations; thermal model; Capacitors; Charge measurement; Corona; Current measurement; Electrodes; Equations; Partial discharge measurement; Partial discharges; Polyethylene; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, Conference Record of the 1992 IEEE International Symposium on
Conference_Location :
Baltimore, MD
ISSN :
1089-084X
Print_ISBN :
0-7803-0649-X
Type :
conf
DOI :
10.1109/ELINSL.1992.246983
Filename :
246983
Link To Document :
بازگشت